Rinnai Infinity REU-V2632FFUG / HD200i REU-VM2632FFUC Continuous Flow Gas Hot Water System Service Manual

Service manual for the Rinnai Infinity REU-V2632FFUG and HD200i REU-VM2632FFUC continuous flow gas hot water systems, covering service, fault finding and parts.


Rinnai Infinity REU-V2632FFUG / HD200i REU-VM2632FFUC Continuous Flow Gas Hot Water System Service Manual - cover page
Brand
Rinnai
Category
Water heater
Document type
Service Manual
Language
English
Pages
50
File format
PDF
File size
3.7 MB
Published
17 November, 2026
Updated
17 November, 2026
MD5 checksum
209A8692635CB55E84DA26C1E33A132E

About this manual

This service manual is for the Rinnai Infinity REU-V2632FFUG and HD200i REU-VM2632FFUC temperature controlled continuous flow gas hot water systems. It is Issue 1, dated 16/12/09, and was produced by Rinnai Australia Engineering & Technical Group.

The manual covers specifications, water flow rates and pressures, dimensions, water controllers, wiring diagrams, dip switch settings, fault finding, maintenance monitor and error history, gas pressure and conversion procedures, dismantling for service, a parts list and an exploded diagram. It includes service contact points and warns that all service work must be carried out by an authorised person.

What's inside

  • Specifications
  • Water Flow Rates and Pressures
  • Dimensions
  • Water Controllers
  • Wiring Diagram
  • Dip Switch Settings
  • Fault Finding
  • Maintenance Monitor / Error History
  • Dismantling for Service
  • Parts List

Specifications

Model numberREU-V2632FFUG / REU-VM2632FFUC
Type of applianceTemperature controlled continuous flow gas hot water system
Combustion systemRoom sealed, fan forced combustion
DimensionsWidth 350 mm, height 600 mm, depth 259 mm
Weight21 kilograms
Gas consumptionNatural gas 16–195 MJ/h; propane gas 16–195 MJ/h
Maximum hot water capacity26 L/min at 25°C rise
Minimum water flow for operation2.4 L/min
Electrical consumption45 W normal; 2 W standby with 1 water controller
Power supplyAppliance: AC 240 V 50 Hz; water controller: DC 12 V

Frequently asked questions

What type of appliance is this?

It is a temperature controlled continuous flow gas hot water system.

What is the minimum water flow required for operation?

The minimum water flow for operation is 2.4 L/min.

How often does Rinnai recommend servicing the appliance?

Rinnai recommends that this appliance be serviced every 3 years.

How many water controllers can be fitted?

A maximum of 4 water controllers can be fitted.

Download PDF (3.7 MB)

More Rinnai Manuals