Operating instructions for PANDA WV 1200 A, WV 1800 A, and WV 2400 A rotary vane vacuum pumps, covering installation, maintenance, and technical specifications.
This manual provides comprehensive operating instructions for the PANDA WV 1200 A, WV 1800 A, and WV 2400 A rotary vane vacuum pumps. It covers safety information, product description, installation procedures, commissioning, maintenance schedules, troubleshooting, and disposal guidelines. The document is intended for technically trained personnel operating these machines in industrial environments. This manual is written in German.
| Nominal suction capacity (50 Hz) | 1050 m³/h (WV 1200 A), 1600 m³/h (WV 1800 A), 2120 m³/h (WV 2400 A) |
|---|---|
| Motor rated power (50 Hz) | 3.5 kW (WV 1200 A), 4.3 kW (WV 1800 A), 6.0 kW (WV 2400 A) |
| Motor rated speed (50 Hz) | 3000 min-1 |
| Sound pressure level (50 Hz) | 59 dB(A) (WV 1200 A), 60 dB(A) (WV 1800 A), 67 dB(A) (WV 2400 A) |
| Operating temperature range | 5 ... 40 °C |
| Maximum gas inlet temperature | 200 °C |
| Oil quantity (Motor side) | 1.6 l (WV 1200 A), 1.6 l (WV 1800 A), 1.7 l (WV 2400 A) |
| Weight | 290 kg (WV 1200 A), 300 kg (WV 1800 A), 520 kg (WV 2400 A) |
The machine components are compatible with gray cast iron, steel, aluminum, and fluoroelastomer (FKM/FPM).
No, the machine is designed for operation in non-explosion-prone environments only.
The machine must be installed horizontally; the inclination must not exceed 1° in any direction.
The discharge must never be closed or throttled, as this can damage the machine.