Omega SSRDC100V, SSR330, SSR660, SSRINT660, SSR3PH660, SSRDIN660 Series Solid State Relays User's Guide

Omega user guide for SSRDC100V, SSR330, SSR660, SSRINT660, SSR3PH660 and SSRDIN660 series solid state relays, covering precautions, specs, wiring and derating.


Omega SSRDC100V, SSR330, SSR660, SSRINT660, SSR3PH660, SSRDIN660 Series Solid State Relays User's Guide - cover page
Brand
Omega
Category
RELAY
Document type
User Manual
Language
English
Pages
12
File format
PDF
File size
1.7 MB
Published
16 November, 2026
Updated
16 November, 2026
MD5 checksum
9AFCDA11FE8004AE66F259862D3C9DB9

About this manual

The OMEGA Solid State Relays are normally open, solid state switching devices with no moving parts. The guide states that they are designed to control 120 V, 240 V, 440 V, or 660 V alternating current and provide zero voltage switching and 4000 VAC isolation between the load terminals and the control signal.

The document covers installation precautions, finned heat sinks, fuse protection, leakage current, model tables, schematics, mechanical drawings, wiring examples, and derating curves. It also lists accessory fuses, fuse blocks, thermal compound, and heat sinks.

What's inside

  • Precautions
  • General Description
  • Finned Heat Sinks (FHS)
  • Fuse Protection
  • Leakage Current
  • AC Output Single Phase Relays
  • AC Output Three Phase Relays
  • Schematics
  • Wiring Examples
  • Derating Curves

Specifications

Isolation voltage4000 VAC
Contact configurationNormally open
Switching methodZero voltage switching
Leakage current in OFF stateTypically 5 to 15 mA
Operating lifeTens of millions of cycles
SSRDC100VDC8 load voltage range0-100 Vdc
SSRDC100VDC40 load current40 A DC
SSR330DC10 control voltage4 Vdc minimum; 32 Vdc maximum
SSR330DC10 load voltage range24 to 330 Vac

Frequently asked questions

What is the load voltage range of the SSR330DC10?

The SSR330DC10 has a load voltage range of 24 to 330 Vac.

What is the typical leakage current when an SSR is OFF?

All SSRs have a typical leakage current of 5 to 15 mA in the OFF state.

Do panel-mount SSRs require a heat sink?

Yes. Panel-mount SSRs must be mounted on a Finned Heat Sink or on a metal plate of adequate size.

What fuse rating should be selected for an SSR?

Select a fuse with a current and voltage rating less than the maximum rating of the relay.

Download PDF (1.7 MB)