Negele Messtechnik TFP Series Temperature Sensor Product Information

Negele Messtechnik TFP series temperature sensors for hygienic measurement in pipes and vessels, with front flush mounting and Pt100 options.


Negele Messtechnik TFP Series Temperature Sensor Product Information - cover page
Brand
Negele Messtechnik
Category
Temperature sensors
Document type
Product Leaflet
Language
English
Pages
4
File format
PDF
File size
1.6 MB
Published
16 November, 2026
Updated
16 November, 2026
MD5 checksum
9E6D71B271F11124BD99DA05BA4AF0DC

About this manual

The Negele Messtechnik TFP series temperature sensors (TFP-41, TFP-44, TFP-51, TFP-161, TFP-181, TFP-164, TFP-184) measure temperature in pipes and vessels with front flush mounting and high accuracy. They feature a hygienic design that is easy to sterilize and are made of stainless steel or PEEK for front flush versions.

Typical applications include controlling CIP/SIP processes, measurement in vessels with agitators, and temperature measurement in UHT plants. The sensors use a G 1/2" hygienic process connection and are available with Pt100 sensing resistors, optional integrated transmitters, and various insertion lengths and cable options.

What's inside

  • Application
  • Application Examples
  • Hygienic Design / Process Connection
  • Features
  • Options / Accessories
  • Specifications
  • Drawings / Installation
  • Accuracy Class Pt100
  • Transmitter mpu-m
  • Conditions for a measuring point according to 3-A-Standard 74-03

Specifications

Process connectionG 1/2" hygienic weld-in sleeve
Insertion length0, 50, 150, 250 mm standard
Protection classIP 69K
Ambient temperature range-50 ...+80 °C
Sensor tip temperature range-50...+250 °C
Operating pressuremax. 10 bar
Pt100 class A accuracy at 0 °C± 0.15 K
MPU-4 output signal4...20 mA analog

Frequently asked questions

What process connection is used for the TFP temperature sensors?

They use a G 1/2" hygienic weld-in sleeve process connection.

What is the maximum operating pressure of the sensors?

The maximum operating pressure is 10 bar, or 6 bar for TFP-44, -164, and -184 models.

What output signal does the MPU-4 transmitter provide?

It provides an analog 4...20 mA output signal.

What is the class A accuracy of the Pt100 sensor at 0 °C?

The tolerance is ± 0.15 K at 0 °C.

Download PDF (1.6 MB)

More Negele Messtechnik Manuals