Installation manual for the MAGNUM Standard Control on/off thermostat, covering startup, sensors, wiring, setback, calibration, LED indications and…
The MAGNUM Standard Control is an electronic thermostat with four functions: room sensor, floor sensor, power regulator, and room sensor with maximum/minimum limiter. It can also be set up for setback temperature.
The manual explains startup, sensor selection, thermostat connection, setback temperature, temperature calibration, Bi-LED indications, and technical data including voltage, load, current, IP class, temperature ranges and sensor values.
| Voltage | 230 VAC AC ± 15%, 50 Hz |
|---|---|
| Maximum load | 3600W (resistive load) |
| Maximum current | 16 Amp |
| Power consumption | 0.5W |
| IP class | IP 21 |
| Power regulator time cycle | 0-30 min |
| Minimum/maximum installation temperature | -20°C to +60°C |
| Minimum/maximum operating temperature | 0°C to 50°C |
| Floor sensor temperature interval | 5°C to 40°C |
| Room sensor temperature interval | 5°C to 40°C |
| Hysteresis | 0.5°C |
| Floor sensor length | 3 meters |
The maximum load is 16A/3600W at 230V.
A sensor malfunction or a disconnected floor sensor.
Connect an external timer to the S and L clamps to lower the temperature by 3°C at desired times.
The floor sensor is 3 meters long and can be extended 10 meters with a proper installation cable.