The Magnum Cv valve datasheet provides flow rates, dimensions, pressure ratings, and electrical specifications for the valve and its controllers.
The Magnum Cv valve datasheet details the performance characteristics of the valve, including service and backwash flow rates, Cv values, and pressure and temperature limits. It also lists the standard connections and dimensions for tank, inlet, outlet, and auxiliary ports.
Electrical information for the valve’s controllers is included, covering operating voltage, power consumption, and transformer requirements. Options for different controller series and injector sizes are described, along with typical installation guidelines.
| Service Cv | 19.5 |
|---|---|
| Backwash Cv | 17.8 |
| Working Pressure | 25 psi–100 psi (1.72–6.9 bar) |
| Water Temperature Range | 35 °F–100 °F (2 °C–38 °C), up to 120 °F (49 °C) |
| Tank Thread Size | 4‑inch 8 UN |
| Inlet/Outlet Connection | 2‑inch NPT or BSPT, Female, CPVC |
| Controller Operating Voltage | 12 V AC |
| Control System Power Consumption | 3 W average |
| Transformer Output Voltage | 12 V AC 400 mA |
The valve operates between 25 psi and 100 psi (1.72 bar to 6.9 bar).
Standard connections include a 4‑inch 8 UN tank thread and 2‑inch NPT or BSPT female CPVC inlet/outlet.
The controller requires a 12 V AC operating voltage.
The control system consumes about 3 watts on average.