About this manual

The CL2C Series is a Leisai integrated closed-loop stepper driver with a built-in controller. It uses an RS485 interface and Modbus RTU protocol, supports control of up to 31 drives, and provides a 16-segment position table (PR) function. The manual covers product introduction, delivery checks, installation, interface and terminal wiring, brake connections, common functions, Modbus RTU, PR functions, and host software.

It also includes safety and installation notes, such as a maximum encoder cable length of 20 m, at least 10 mm clearance between the drive and a cabinet or other equipment, and at least 30 mm of wiring space above and below the drive. The manual gives procedures for configuration, jog operation, homing, triggering, parameter import/export, and RS485 communication testing. This manual is written in Chinese.

What's inside

  • Product Introduction
  • Delivery Check
  • Installation Environment and Drive Mounting
  • Bus Stepper Wiring Diagram
  • Terminals and DIP Switches
  • Brake Connection
  • Common Functions
  • Modbus RTU
  • PR Functions
  • Host Software

Specifications

Communication interfaceRS485
Communication protocolModbus RTU
Maximum controllable drives31
Position table capacity16 segments
Supported closed-loop stepper motor frame sizes28, 35, 42, 57, 60, 86
Maximum encoder cable length20 m
Minimum clearance from cabinet or other equipment10 mm
Wiring space above and below the drive30 mm

Frequently asked questions

What communication interface and protocol does the CL2C Series use?

It uses an RS485 communication interface based on the Modbus RTU protocol.

How many drives can be controlled at the same time?

Up to 31 stepper drives can be controlled at the same time.

Which motor frame sizes are supported?

The drive supports closed-loop stepper motors with 28, 35, 42, 57, 60, and 86 frame sizes.

What is the maximum encoder cable length?

The encoder cable can be up to 20 m long.