This document is a data sheet for DURAGROUT DS-176.8-0417, a ready-mixed, non-shrink, non-metallic, flowable, high-strength structural grout manufactured by LATICRETE International, Inc. The product is designed for use in precise machine bases, pump and equipment bases, structural columns, machine tools, compressors, and anchor bolts. It features high early and ultimate strengths without intermediate or latent shrinkage and remains stable under compressive loading, impact, lateral thrusts, high heat, or continuous vibration.

What's inside

  • Product Description
  • Uses
  • Advantages
  • Technical Data
  • Installation
  • Mixing Instructions
  • Curing Instructions
  • Warranty
  • Safety Cautions

Specifications

Product TypeReady-mixed, non-shrink, non-metallic, flowable, high-strength structural grout
Packaging50 lb (22.7 kg) bag
Approximate Coverage0.4 ft3 (12.5 L) per bag
Shelf LifeOne (1) year in unopened bags
Split Tensile Strength590 psi (4.1 MPa) at 28 days
Initial Setting TimeApproximately 5 hours

Frequently asked questions

What are the water requirements for mixing DURAGROUT DS-176.8-0417?

For plastic consistency, use 3.5 qts (3.2 L) per 50 lb bag. For fluid consistency, use 4.5 qts (4.3 L) per 50 lb bag.

What is the recommended curing time for DURAGROUT?

Exposed DURAGROUT must be protected and cured immediately after placement for a period of 72 hours.

What are the limitations for placing DURAGROUT?

Do not mix more than can be placed in 30 minutes, and avoid placement when temperatures are below 40 °F (5°C) within 24 hours.