KOMECO Solar Heating System User and Installation Manual

User and installation manual for KOMECO solar water heating system, covering collectors, reservoirs, water quality, electrical backup and troubleshooting.


KOMECO Solar Heating System User and Installation Manual - cover page
Brand
KOMECO
Category
Water heater
Document type
User Manual
Language
Portuguese
Pages
24
File format
PDF
File size
1.5 MB
Published
11 November, 2026
Updated
11 November, 2026
MD5 checksum
1D16806DE4C4DBCF893D29B4089E20A2

About this manual

The KOMECO user and installation manual describes a solar water heating system for homes and establishments that need hot water. It covers KOCS PR, KOCS AB and KOCS MX solar collectors and BP/AP thermal reservoirs, and explains how the collectors and reservoirs work.

The document gives technical specifications for collectors and reservoirs, water quality requirements for AISI 304 and AISI 316, installation recommendations, electrical backup and wiring information, possible problems and solutions, and warranty and manufacturer information. This manual is written in Portuguese.

What's inside

  • Solar Heater
  • Technical Specifications
  • Water Quality
  • Operation
  • Recommendations
  • Electrical Backup
  • Electrical Connection
  • Possible Problems and Solutions
  • Warranty and Manufacturer Information

Specifications

Collector tube diameter22 mm
Collector working pressureMaximum 40 m.c.a.
Thermal reservoir inner cylinder materialAISI 304 or AISI 316 stainless steel
Thermal insulationExpanded polyurethane
Electrical resistance power3000 W or 6000 W
Low-pressure working pressure49.03 kPa (5 m.c.a.)
High-pressure working pressure392 kPa (40 m.c.a.)
Water pHBetween 7 and 8

Frequently asked questions

What is the maximum working pressure of the KOMECO solar collectors?

The manual lists a maximum working pressure of 40 m.c.a. for the collectors.

What water pH range does the manual specify?

It specifies a pH between 7 and 8 for both AISI 304 and AISI 316 reservoirs.

How often should the sacrificial anode be inspected and replaced?

The manual recommends inspecting it every 6 months and replacing it every year, or sooner if the technical service identifies the need.

What should be done if air is trapped in the piping?

Open all consumption points until all air is removed; if the problem continues, request technical service.