KOMECO PS 1100/1100M ELECTRONIC PRESSURE SWITCH WITHOUT PRESSURE GAUGE AND WITH PRESSURE GAUGE INSTALLATION MANUAL
This manual provides instructions for the installation and operation of the KOMECO PS 1100 and PS 1100M electronic pressure switches. It details the technical specifications, including voltage compatibility and maximum pressure limits, and explains the device's functionality in maintaining water network pressure. This manual is written in Portuguese.
| Voltage | 110V - 220V Bivolt |
|---|---|
| Max Working Pressure | 10 bar |
| Frequency | 60Hz |
| Max Water Temperature | 90°C |
| Max Current | 10A |
| Connections | 1'' (entrada e saída) |
| Protection Class | IP 65 |
| Max Operation Power | 1.1Kw |
The factory activation pressure is set to 8 meters of water column (mca).
The red LED indicates a failure, meaning the pressure switch does not detect water or reach the necessary operating pressure.
Press the red 'restart' button to reset the device and normalize system operation.