This is a KOMECO brand KO 26D HOME model gas water heater user manual, which mainly introduces the features, installation and use methods of the product
This manual provides instructions for installing and operating the KOMECO KO 26D HOME gas water heater. It includes safety precautions, installation requirements, usage guidelines, and troubleshooting. The unit features a digital control panel, forced exhaust, and safety sensors to prevent overheating and gas leaks. Installation must be performed by certified KOMECO technicians and comply with local regulations and NBR 13103 standards.
The manual also details technical specifications, including gas type (GLP or GN), water flow rate, power consumption, and dimensions. It covers maintenance tips, warranty information, and how to interpret error codes. Users are advised to read the manual thoroughly before installation and to contact KOMECO’s SAC for support or certified installation services. This manual is written in Portuguese.
| Gas Type | GLP or GN |
|---|---|
| Water Flow Rate | 26 L/min (with 20°C rise) |
The maximum water flow rate is 26 liters per minute with a 20°C temperature rise.
It cannot be installed inside cabinets, bathrooms, or bedrooms.
The digital panel can be set from 30°C to 65°C.
Yes. The manual states that a chimney is mandatory for this heater.