User manual for the Jinan Zhize V2.1 explosion-proof hydrogen sensor, covering installation, hardware connections, communication protocols, analog/digital…
This manual provides instructions for the installation, use, and maintenance of the Jinan Zhize V2.1 explosion-proof hydrogen sensor. It details the product's features, including a wide measurement range, high precision, and robust cast aluminum housing designed for harsh environments.
The document covers hardware connection procedures, including interface descriptions and wiring color codes for power and signal lines. It also explains the digital Modbus RTU communication protocol and provides formulas for converting analog 4-20mA and 0-5V/0-10V outputs into hydrogen concentration values (ppm). Finally, it lists common troubleshooting steps for connection and output issues. This manual is written in Chinese.
| H2 Measurement Range | 0-1000ppm / 0-40000ppm |
|---|---|
| Measurement Method | Electrochemical probe |
| Response Time | Less than 30 seconds |
| Measurement Accuracy | 3%F.s |
| Interface Form | Analog (Voltage/Current) / Digital (RS485) |
| Power Supply | 12V-24VDC |
| Operating Temperature | -20°C to +50°C |
| Explosion Proof Rating | ExdⅡCT6 |
| Dimensions | 172x142x90mm |
The sensor host is warranted for 2 years, and the gas probe is warranted for 1 year.
The default address for all devices is 1.
The host polling interval and wait response time must be set to 200ms or above.