Jinan Zhize Explosion-proof Ammonia Sensor User Manual

This manual provides installation, wiring, communication protocol, and troubleshooting instructions for the Jinan Zhize explosion-proof ammonia sensor.


Jinan Zhize Explosion-proof Ammonia Sensor User Manual - cover page
Brand
Jinan Zhize
Category
Other Electronics
Document type
User Manual
Language
Chinese
Pages
22
File format
PDF
File size
953 KB
Published
21 October, 2026
Updated
21 October, 2026
MD5 checksum
D1D0E58CC8890B735D56DA2EE495137D

About this manual

This user manual covers the explosion-proof ammonia sensor designed for harsh industrial environments. It details the product overview, functional features, and technical specifications, including measurement ranges from 0-100ppm to 0-50000ppm and response times under 60 seconds.

The document provides comprehensive guidance on hardware connections, including power supply requirements (12-24VDC) and RS485 interface wiring. It explains the Modbus RTU communication protocol, data frame formats, and register addresses. Additionally, it includes calculation methods for converting analog voltage/current outputs to ammonia concentration values. This manual is written in Chinese.

What's inside

  • Product Overview
  • Hardware Connection
  • Digital Sensor Communication Protocol
  • Analog Sensor Parameters
  • Common Questions
  • Warranty and After-sales

Specifications

Measurement Range0-100ppm / 0-1000ppm / 0-5000ppm
Measurement MethodElectrochemical probe
Response TimeLess than 60 seconds
Accuracy3%F.s
InterfaceAnalog (Voltage/Current) / Digital (RS485)
Power Supply12V-24VDC
Operating Temperature-20℃ to +50℃
Explosion Proof RatingExdⅡCT6

Frequently asked questions

What is the default probe type for the sensor?

The default probe used is the 4G type probe.

How do I calculate NH3 concentration from a 0-10V voltage output?

Multiply the voltage in mV by 0.01 to get the value in ppm (e.g., 3515mV = 35.15ppm).