Technical specification for James Hardie Axon Panel installation and maintenance in timber-framed buildings.
This document is a technical specification for the Axon Panel, a lightweight cement composite manufactured by James Hardie. It details application, design, installation, and maintenance practices specifically for use in timber-framed buildings within New Zealand.
The manual covers two primary construction methods: direct fixing to framing and cavity construction using CLD Structural Cavity Battens. It provides comprehensive guidance on panel layout, jointing, finishing with flexible sealants, safety working practices, product sizes, and accessories.
| Base Composition | Portland cement, ground sand, cellulose fibre and water |
|---|---|
| Groove Width (133/400) | Nominal 10mm wide |
| Groove Depth | 2.25mm deep |
| Max Wind Pressure | Up to 2.5kPa |
The panel is made from an advanced lightweight cement composite consisting of portland cement, ground sand, cellulose fibre and water.
The manual covers direct fixing to framing and cavity construction using CLD Structural Cavity Battens.
The grooves on the face panel are nominal 10mm wide x 2.25mm deep and spaced at 133mm centres.