James Hardie Manuals

ManualLib has 2 James Hardie manuals. Every file can be read online or downloaded as a PDF for free.

Application Note 1Product Leaflet 1

Key facts

Manuals
2
Languages
EN
Last added
2026-09-30

Latest James Hardie manuals

Which document do I need?

Application Note

How to use the product for one specific task, with worked examples.

Questions answered in James Hardie manuals

What is the minimum acoustic insulation density required?

The acoustic insulation must have a minimum density of 9.6 kg/m³.

From: James Hardie Fire and Acoustic Design Manual

What is the recommended spacing for the James Hardie Acoustic Floor Channel?

The Acoustic Floor Channel should be spaced at a maximum of 450 mm centre.

From: James Hardie Fire and Acoustic Design Manual

What is the minimum ground clearance for installing James Hardie external cladding?

The cladding must be installed with at least a 150 mm clearance to the earth.

From: James Hardie JHML112290A External Cladding Technical Specification

Which fasteners are required for timber framing?

For timber framing, use 2.8 × 30 mm fibre‑cement nails for 4.5 mm and 6 mm thick sheets, and ensure fasteners are at least Class 3 external grade.

From: James Hardie JHML112290A External Cladding Technical Specification