Huawei SUN2000 8KTL-28KTL Quick Installation Guide

Quick installation guide for Huawei SUN2000 8KTL-28KTL inverters, covering mounting, electrical connections, safety, and parameter settings.


Huawei SUN2000 8KTL-28KTL Quick Installation Guide - cover page
Brand
Huawei
Category
inverter
Document type
Quick Start Guide
Language
Chinese
Pages
10
File format
PDF
File size
1.1 MB
Published
21 November, 2026
Updated
21 November, 2026
MD5 checksum
6848826DC7C15790F1266A707120BBA1

About this manual

This guide provides step-by-step instructions for installing Huawei SUN2000 8KTL-28KTL inverters, including mounting on walls or racks, connecting AC and DC cables, and setting up grid parameters. Safety precautions are emphasized, such as using insulated tools and verifying all connections before powering on. The guide also references the full user manual for detailed configurations and includes a grid standard code table for international compatibility.

Installation involves selecting appropriate mounting hardware, securing the inverter, connecting protective grounding, and properly wiring AC and DC inputs. The guide specifies cable cross-sections based on model, and includes warnings against incorrect DC polarity or improper shutdown procedures. After installation, users must verify all connections and set grid parameters such as voltage standards and time settings before connecting to the grid. This manual is written in Chinese.

What's inside

  • System Installation
  • Mounting the Inverter
  • Electrical Connections
  • Grounding
  • AC Output Connection
  • DC Input Connection
  • Post-Installation Checks
  • Monitoring Parameter Settings
  • System Power-Up
  • Grid Standard Codes

Specifications

Weight40kg for 8KTL/10KTL/12KTL; 48kg for 15KTL/17KTL/20KTL/23KTL/28KTL
Recommended DC Cable Cross-Section4.0mm² (12AWG) for 8KTL/10KTL/12KTL; 6.0mm² (10AWG) or 10.0mm² (8AWG) for 15KTL-28KTL
AC Output Connector4-core outdoor cable (L1, L2, L3, N) for 15KTL-28KTL; 3-core for 28KTL

Frequently asked questions

What is the recommended cable cross-section for the DC input?

For 8KTL/10KTL/12KTL models, use 4.0mm² (12AWG); for 15KTL-28KTL models, use 6.0mm² (10AWG) or 10.0mm² (8AWG).

What should I do if I reverse the DC input polarity?

Do not immediately turn off the DC SWITCH. Disconnect the PV string cables or wait until the voltage drops to a safe level, then turn off the DC SWITCH and reconfigure the polarity.

What grid standard code should I select for China’s low-voltage grid?

Select 'NB/T 32004' for China’s low-voltage grid.