Hongrun OHR-D13 Series Single-Phase LED Display Power Transmitter User Manual

Chinese user manual for the Hongrun OHR-D13 Series single-phase LED display power transmitter: specs, safety, panel, and parameter settings.


Hongrun OHR-D13 Series Single-Phase LED Display Power Transmitter User Manual - cover page
Brand
虹润
Category
Voltage and Current Measurement
Document type
User Manual
Language
Chinese
Pages
8
File format
PDF
File size
862 KB
Published
10 November, 2026
Updated
10 November, 2026
MD5 checksum
11DB7BCEF6E9B168E7118E285F632D69

About this manual

This is the Chinese user manual for the Hongrun OHR-D13 Series single-phase LED display intelligent power transmitter. According to the introduction, the unit uses a low-power microprocessor with a five-digit LED display and alarm indicators, measures voltage, current, active and reactive power, power factor, frequency and energy on single-phase lines, and can transmit data through RS485/RS232 or analog output.

The manual covers the technical parameters, safety notices and the installation and startup flow, the front panel symbols, keys and error codes, and the parameter setting menus (system, input, communication, alarm, decimal point and analog output settings). It also includes ordering notes describing selectable extended functions. This manual is written in Chinese.

What's inside

  • 产品介绍
  • 技术参数
  • 安全注意事项
  • 安装使用流程
  • 订货须知
  • 仪表的面板及显示功能
  • 操作按键
  • 错误故障代码提示
  • 参数设置
  • 主菜单显示

Specifications

Voltage measuring range0.0 to 500.0 V AC
Current measuring range0.03 to 5 A AC
Frequency range45 to 65 Hz
Voltage input impedance2 MΩ
Current input impedanceless than 0.1 Ω
Analog output4-20 mA, 0-20 mA, 0-10 mA, 1-5 V, 0-5 V
Alarm outputRelay, AC220V/2A, DC24V/2A (resistive load)
CommunicationRS485/RS232, 1200 to 9600 bps, MODBUS RTU
Power supplyAC/DC 100 to 240 V, 50/60 Hz
Mounting35 mm DIN rail
Dimensions77 x 132 x 57 mm (W x H x D)
Ambient temperature-10 to 60 °C

Frequently asked questions

What power supply does the OHR-D13 Series require?

It uses a switching power supply of AC/DC 100 to 240 V, 50/60 Hz.

What communication interface and protocol does it support?

It provides RS485/RS232 communication interfaces with a settable baud rate of 1200 to 9600 bps and uses the MODBUS RTU protocol.

How is the instrument mounted?

It is mounted on a 35 mm DIN rail.

What does the error code ERR-1 mean?

ERR-1 indicates an internal parameter self-check error.

Does the instrument leave the parameter setting mode automatically?

Yes, if there is no operation for 10 minutes the system automatically returns to the initial screen.