Installation guide for Hitachi WJ200 series inverters covering EMC compliance, filter selection, cable length, shielding, and grounding requirements.
This guide provides detailed instructions for installing Hitachi WJ200 series inverters to meet electromagnetic compatibility (EMC) standards. It covers selecting appropriate line filters, minimizing radiated interference, proper motor cable length (max 50m), shielding and grounding techniques, and compatibility with different inverter models. The document also includes warnings about safety precautions, such as waiting 60 seconds after power-off before touching terminals, and notes on grounding requirements for safe operation.
The guide is structured into chapters covering warnings, filter installation, motor cable influence, and technical specifications for WJ200 filters. It references EMC standards like EN 61800-3 and provides tables for filter selection based on inverter model and voltage specifications. Installation recommendations include using metal cabinets, avoiding parallel cable runs, and ensuring proper grounding to prevent electric shock and interference. This manual is written in Chinese.
| EMC Compliance Standard | EN 61800-3 (EN 55011 group 1, Category C1/C2/C3) |
|---|
The motor cable length should not exceed 50m to avoid electromagnetic emission and capacitive currents.
Wait at least 60 seconds after switching off the line voltage before touching terminals or removing protective covers to avoid electric shock.
The inverter complies with EN 61800-3 (EN 55011 group 1, Category C1/C2/C3).