German product manual for Hitachi L100 series frequency inverters: mounting, CE-EMV installation, wiring, programming, fault messages and technical data.
The Hitachi L100 series frequency inverters are electrical components intended for commercial use, controlling the speed of three-phase motor drives and designed for installation in machines or assembly with other components into a machine. The manual opens with safety and warning notes and the intended use, then covers checking the scope of delivery, the unit layout shown on the L100-004NFE and L100-015HFE, mounting, CE-EMV installation with interference suppression filters, and the connection and description of the power and control terminals.
Programming is described step by step: the built-in operating panel, initialization to the factory setting, commissioning via the panel, fault acknowledgement/reset, and an overview and description of the functions. Later chapters cover fault messages and troubleshooting, maintenance and inspection, programming via the optional DOP or DRW remote operator, technical data, dimensions, options, and the technical data of the interference suppression filters. A type code explains the model designation: N for 1 or 3-phase 200–240 V (0.25–2.2 kW), H for 3-phase 380–460 V (0.37–7.5 kW) and E for the European version. This manual is written in German.
| Rated output (L100-004NFE) | 1–360 Hz, 200–240 V 3-phase, 2.6 A |
|---|---|
| Input (L100-004NFE) | 50/60 Hz, 200–240 V, 1-phase 5.8 A or 3-phase 3.4 A |
| Power range, N types | 0.25–2.2 kW at 200–240 V (1 or 3-phase) |
| Power range, H types | 0.37–7.5 kW at 380–460 V (3-phase) |
| Permissible ambient temperature | -10 to +40 °C; up to +50 °C with carrier frequency below 2.1 kHz, output current reduced to 80% and cover removed |
| Emission standard | EN 61800-3 (EN 55011 Group 1, Class B) |
| Remote operator interface | RS422 serial interface |
| Max. motor cable length with filter | 50 m |
They are components for commercial use, intended to control speed-regulated drives with three-phase motors and to be built into machines or assembled with other components into a machine.
At least 5 minutes, because the DC link capacitors remain at dangerously high voltage after the mains is switched off.
No, the Stop key must not be used for emergency-stop purposes; it can be deactivated with function b87.
N types are for 200–240 V single or three phase with 0.25–2.2 kW, H types for 380–460 V three phase with 0.37–7.5 kW.