Hesai OT128 128-line mechanical LiDAR user manual covering safety notices, installation, electrical interfaces, point cloud data format, settings and…
This is the Chinese user manual for the Hesai OT128 128-line mechanical LiDAR, document version O01-zh-240810. It explains how to obtain the latest manual and technical support, then covers safety notices and environment/personnel assessment, the product introduction (working principle, basic structure, channel distribution, laser emission positions, technical parameters), and first use: mechanical installation, electrical interface pin definitions and connector handling, the optional junction box, network settings on the receiving host under Windows and Ubuntu, and auxiliary tools.
Later sections describe the point cloud data packet format, the parameter interface (network connection, function and status settings, time synchronization, LiDAR information, operating status data, upgrade and logs), the communication protocol, instrument maintenance and troubleshooting, plus appendices on channel distribution data, absolute time of point cloud data, reflectance nonlinear mapping and legal statements. Safety content notes that the product is a Class 1 laser product, has no power switch and runs as soon as power is applied, and that the housing can become hot during operation. This manual is written in Chinese.
| Product | OT128 128-line mechanical LiDAR |
|---|---|
| Laser class | Class 1 |
| Laser safety standards | IEC 60825-1:2014, EN 60825-1:2014, 21 CFR 1040.10 and 1040.11 |
| Channel numbering | From top to bottom, starting at 1 |
| Recommended storage temperature | 23 ± 5℃ |
| Recommended storage humidity | 30% ~ 70% |
| Document version | O01-zh-240810 |
It is a Class 1 laser product, compliant with IEC 60825-1:2014, EN 60825-1:2014 and 21 CFR 1040.10 and 1040.11 (with the deviation noted in Laser Notice No. 56).
No. The product has no power switch and starts running as soon as power is applied.
Switch off the product and let it cool for half an hour before touching, since contact can cause burns.
Store it in a ventilated, dry place, with a recommended temperature of 23 ± 5℃ and humidity of 30% ~ 70%.