User manual for the GYS GYSPACK 400/600 booster, covering safety instructions, internal battery testing, vehicle starting and troubleshooting.
The GYS GYSPACK 400/600 is a self-contained starter designed to start vehicles equipped with a 12 V lead-acid battery. It is powered by a high-performance battery, and the manual states that it must be recharged after each use and left connected to the power supply until the next use. The manual contains operating rules and personal safety provisions and should be read carefully before first use.
The document describes the product interface and indicator lights, the internal battery test button, and the vehicle starting procedure, including clamp connection order and the 3-minute wait / 6-second maximum attempt limits. It also covers the 12 V socket cable, limited to 10 A and intended only for memory saving, plus a table of faults, causes and remedies, maintenance, regulations and disposal.
| Compatible vehicle battery | 12 V lead-acid battery (6 cells of 2 V) |
|---|---|
| Maximum start attempt duration | 6 seconds |
| Interval between start attempts | 3 minutes |
| 12 V socket current limit | 10 A |
| Maximum ambient temperature | Do not place near heat sources or temperatures above 60°C |
| Charger safety class | Class II |
| Booster safety class | Class III |
It is designed for vehicles with a 12 V lead-acid battery made of six 2 V cells.
Recharge it after each use and leave it connected to the power supply until the next use.
It means recharging is mandatory, and the device must not be used while the red light is on.
No. It is intended only for memory saving and must not be used for starting or as a 12 V power source.