This file is the user manual of GYS EXPERT 110 welding machine
This document is the user manual for the GYS EXPERT 110 welding machine. It provides essential information regarding the device's components, such as the electrode holder, earth clamp, and power switch. The manual outlines the correct operating environment, specifying temperature ranges for operation and storage, as well as humidity and altitude limits. This manual is written in Czech.
| Storage Temperature | -25 to +55°C |
|---|---|
| Maximum Altitude | 1000 m |
| Minimum Humidity | ≥ 50% at 40°C |
| EMC Class | Class B |
The minimum safety distance to flammable materials is 11 meters.
No, persons with pacemakers should not work with the device without a doctor's consent due to electromagnetic fields.