German operation manual for Graco High-Flo pumps used to circulate lacquers at low pressure and medium volume.
This manual covers Graco High-Flo pumps for circulating lacquers at low pressure and medium volume. It states that the pump is not to be used for flushing or cleaning lines with corrosive, acidic, abrasive line cleaners or similar fluids.
It includes warnings, installation, grounding, mounting, operation, maintenance, troubleshooting, repair, parts, dimensions, and technical data. The manual also lists model-specific operating pressures, connection types, and materials. This manual is written in German.
| Intended use | Circulating lacquers at low pressure and medium volume |
|---|---|
| Not for | Flushing or cleaning lines with corrosive, acidic, or abrasive cleaners |
| Maximum total length of conductive material hoses | 150 m |
| Maximum total hose resistance | 29 Megaohm |
| Mounting bolt embedment in concrete | at least 152 mm |
| Maximum operating pressure (model 243740) | 500 psi (3.5 MPa, 35 bar) |
| Maximum air input pressure (J_60 pump conversion) | 75 psi |
They are used for circulating lacquers at low pressure and medium volume.
No, it is not to be used for flushing or cleaning lines with corrosive, acidic, abrasive line cleaners or similar fluids.
Use a grounding cable and clamp; remove the green screw at the bottom of the air motor and reinstall it through the eyelet at the end of the grounding cable.
It must be replaced immediately if its total resistance exceeds 29 Megaohm.