This manual provides instructions on how to repair Dura-Flo 1800 (430 cc) and 2400 (580 cc) lowers.
This manual provides professional repair instructions for Graco Dura-Flo 1800 (430 cc) and Dura-Flo 2400 (580 cc) lowers used in pumps, sprayers, and fluid handling systems. It includes detailed safety warnings regarding fire, skin injection, and equipment misuse, as well as specific procedures for pressure relief and required tools.
| Maximum Fluid Working Pressure (430 cc) | 32 MPa (324 bar, 4700 psi) |
|---|---|
| Maximum Fluid Working Pressure (580 cc) | 23 MPa (234 bar, 3400 psi) |
| Outlet Size | 3/4 in. NPT (m) |
The maximum fluid working pressure is 32 MPa (324 bar, 4700 psi).
The maximum fluid working pressure is 23 MPa (234 bar, 3400 psi).
The standard outlet is a 3/4 in. NPT (m).