Manual for the Graco ProBell 3A4858G rotary applicator covering installation, operation, maintenance, and safety for electrostatic coating in hazardous…
The manual provides detailed guidance for the ProBell 3A4858G rotary applicator used in electrostatic coating applications in Class I Division 1 or Zone 1 hazardous areas. It includes related manuals, part number matrices, available models, certifications, warnings, system description, installation steps, operation procedures, maintenance checklists, troubleshooting, repair instructions, parts lists, accessories, dimensions, performance tables, and technical specifications.
Safety warnings emphasize fire and explosion hazards, electric shock, equipment misuse, plastic parts cleaning, entanglement, and toxic fluid hazards. The document specifies maximum air pressure of 100 psi (0.7 MPa, 7.0 bar) and maximum fluid working pressure of 150 psi (1.03 MPa, 10.3 bar). It also details grounding requirements, interlock setup, and daily maintenance routines. This manual is written in Chinese.
| Maximum Air Pressure | 100 psi (0.7 MPa, 7.0 bar) |
|---|---|
| Maximum Fluid Working Pressure | 150 psi (1.03 MPa, 10.3 bar) |
| Certification | 2575II 2G < 350 mJ T6 PTB 16 ATEX 5005 EN 50176 Type B-L |
The maximum air pressure is 100 psi (0.7 MPa, 7.0 bar).
The maximum fluid working pressure is 150 psi (1.03 MPa, 10.3 bar).
Only Group IIA or Group D materials may be used with solvent-based models.