Bulgarian operation, repair and parts manual for Graco Fine Finish HVLP sprayers covering models 25A187, 257829, 257830, 257831, 25A186, 257833, 257834 and…
This manual covers Graco Fine Finish HVLP sprayers used for applying fine final finishes with portable sprayers. It includes safety warnings, electrical and grounding requirements, component identification, setup, fluid preparation, connection of power, fluid and air, pressure release, and operating tips.
It also covers maintenance, troubleshooting, repair procedures such as gun disassembly and assembly and turbine replacement, wiring diagrams, technical specifications, parts lists, and the standard Graco warranty.
| Maximum working pressure | 10 psi (0.07 MPa, 0.7 bar) |
|---|---|
| Electrical supply | 240V AC, 50 Hz, 15A with grounded outlet |
| Extension cord | 3-wire, 12 AWG, 50 ft (15 m) with grounding plug |
| Air hose | 30 ft x 1 in (9.144 m x 0.0252 m) |
| Hose length | Model-dependent: 20 ft (6.096 m) or 30 ft (9.144 m), with 4 ft (1.22 m) on some models |
The maximum working pressure is 10 psi (0.07 MPa, 0.7 bar).
They require 240V AC at 50 Hz and 15A with a grounded outlet.
Use a 3-wire extension cord of at least 12 AWG and 50 ft (15 m) with a grounding plug.