Operation manual for the GeoSIG GSR/GSD-24 recorder covering installation, operation settings, self-test, maintenance and functional description.
The GeoSIG GSR/GSD-24 Operation Manual describes the GSR-24/GSD-24 recorder, including its housing, LCD, LEDs, printed circuit boards, internal battery, battery charger and connectors. It covers incoming inspection, site selection, installation, supply voltage selection, mounting, first start and setting operation parameters.
The manual also addresses troubleshooting and maintenance, including self-test functions, and gives a functional description of signal conditioning, digitising, triggering, data recording, clock functions and data retrieval. Appendices cover specifications, GSR-24 connectors and the GSBU_GSR24 data protocol.
| Main Battery Type | Lead-acid |
|---|---|
| Main Battery Replacement Interval | 3 years from date of production, assuming operation at a steady 20°C or below |
| Backup Battery Replacement Interval | 5 years from date of production, assuming operation at a steady 20°C or below |
| Backup Battery Runtime Without Main Power | One year |
Turn the main switch to Stop, unplug the power connector and disconnect the main battery.
It provides power to the clock chip and memory module for a total time of one year.
No. The manual states that you must never use any other battery than the ones supplied or approved in writing by GeoSIG.
The listed main batteries have a replacement interval of 3 years from date of production, assuming operation at a steady 20°C or below.