GeoSIG Ltd GSR-12 / 16 / 18 AS-12 / 16 GCR-12 / 16 User Manual
This document serves as the user manual for GeoSIG Ltd's GSR, GCR, and AS series instruments, which are seismographs used for recording seismic data. The manual applies to specific firmware versions and provides comprehensive guidance on safety, incoming inspection, and the physical description of the housing and internal components like batteries and circuit boards.
The guide details the installation process, including site selection, power supply considerations, and mounting requirements. It explains how to configure parameters, utilize various triggering methods (threshold, STA/LTA, time, software, and external), and manage data recording and intensity scales. Additionally, it covers troubleshooting procedures, maintenance schedules for batteries, and cybersecurity recommendations.
| Main Battery Type | FIAMM FG20721, 12V 7.2Ah |
|---|---|
| Backup Battery Type | Varta CR 1/2 AA SLF |
| Main Battery Replacement Interval | 3 years from date of production |
| Backup Battery Replacement Interval | 5 years from date of production |
The main battery should be replaced every 3 years, and the backup battery every 5 years from the date of production.
Users must flip the main switch to OFF, disconnect the power supply, disconnect the main battery, and ensure the Active Charge LED is OFF.
Yes, an external DC power supply is an optional accessory that can be connected to the instrument.