Owner's manual for Genesis gasoline engines (models 160F-G420F): safety, controls, operation, maintenance, troubleshooting and specifications.
This owner's manual covers Genesis gasoline engines, including models 160F, 168F-1, 168F-2, 170F, 173F, 177F, 182F, 188F, 190F, G120F, G160F, G180F, G200F, G210F, G240F, G270F, G340F, G390F and G420F. It explains safety precautions, component and control locations, pre-operation checks, starting and operating procedures, maintenance, storage and transport, troubleshooting, specifications, wiring diagrams and optional parts.
The manual also lists engine specifications such as type, rated power, torque, displacement, compression ratio, valve and spark plug clearances, dimensions, weight, noise level and battery requirements for electric-start models.
| Engine type | Single cylinder, 4-stroke, forced air cooling, OHV |
|---|---|
| Fuel consumption | ≤395 g/kW·h |
| Idle speed | 1800±150 rpm |
| Speed fluctuating ratio | ≤10% |
| Noise level (smaller models) | ≤70 dB(A) |
| Noise level (larger models) | ≤80 dB(A) |
| Compression ratio (G120F/G160F/G200F models) | 8.5:1 |
| Compression ratio (G340F/G390F/G420F models) | 8:1 |
| Spark plug clearance | 0.7-0.8 mm |
| Valve clearance | Intake 0.10-0.15 mm; exhaust 0.15-0.20 mm |
| Lubricating mode | Splash |
| Rotation | Anti-clockwise (from P.T.O. side) |
| Air cleaner | Semi-dry, oil bath, foam filter |
| Starting mode | Recoil start; recoil/electric starting on D types |
| Battery (optional, electric-start models) | 12 V, 18 Ah or more |
Leave it in the OFF position to prevent carburetor flooding and reduce the possibility of fuel leakage.
Turn the engine switch to the OFF position.
Use CLOSE for a cold engine and OPEN for operation after starting or for restarting a warm engine.
Use a battery rated at 12 V, 18 Ah or more.