This application note provides a quick start guide for the System Management Bus (SMBus), covering topology, electrical specifications, data transfers…
The document introduces the System Management Bus (SMBus) as a two-wire interface based on I2C principles, designed to allow system components like smart batteries to communicate with the host. It details how SMBus reduces pin count by providing a control bus for passing messages between devices.
Key topics covered include SMBus topology and electrical specifications (AC/DC parameters), data transfer formats, usage models involving hosts, masters, and slaves, packet error checking, and bus protocols. The guide also explains the differences between SMBus 2.0 and I2C.
| Operating frequency range | 10 KHz to 100 KHz |
|---|---|
| Data input high voltage (VIH) | 2.1 VDD |
| Nominal bus voltage | 2.7 to 5.5 V |
SMBus provides a control bus for the system to pass messages to and from devices instead of using individual control lines, helping to reduce pin count and system wires.
Besides the General Call Address, SMBus systems can have 127 devices.