This application note describes the design of Indirect Power Factor Correction for 3-phase AC motor V/Hz speed open loop applications using the Freescale…
This document details the design of an Indirect Power Factor Correction (PFC) system for 3-phase AC motor V/Hz speed open loop applications. It utilizes the Freescale 56F80x Digital Signal Controller (DSC) to integrate PFC control alongside main motor control tasks, reducing system cost and complexity by replacing multiple ICs with software implementation.
The application is based on the 56F80x PWM module and is designed for use with the 56F803 and 56F805 Evaluation Module (EVM) platforms. The system operates on a 360V DC bus derived from an 115-230V AC input, ensuring input current harmonics comply with IEC 1000-3-2 standards.
| Input power supply voltage | 115-230V AC |
|---|---|
| Input power supply frequency | 50/60 Hz |
| Nominal output voltage | 360V DC +/- 10% |
| Nominal output power | 180W |
| PWM resolution | 15-bits |
| Targeted devices | 56F803/805EVM platforms |
The use of a digital PFC replaces a number of ICs and reduces the system cost.
The application is targeted for the 56F803 and 56F805 Evaluation Module (EVM) platforms.
Yes, the input current harmonic content is designed to comply with standard IEC 1000-3-2.