Safety data sheet for Franke's acid milk system cleaner, covering hazards, handling, and disposal.
This document is a safety data sheet for Franke's Acid Milk System Cleaner, detailing its chemical composition, first-aid measures, fire-fighting methods, and environmental precautions. It includes handling and storage instructions, exposure controls, and disposal guidelines. The product contains phosphoric acid and is not classified under GHS. It is intended for use in cleaning milk systems and requires proper ventilation and protective equipment during handling.
The cleaner is fully miscible with water, has a pH of 2.44, and is not flammable or explosive. In case of exposure, rinse affected areas with water and seek medical advice if symptoms persist. Disposal should follow local regulations, and packaging must be disposed of according to official rules.
| pH-value at 20 °C | 2.44 |
|---|---|
| Chemical Composition | 7664-38-2 phosphoric acid < 10% |
| Appearance | Light blue fluid |
| Solubility | Fully miscible with water |
The pH-value at 20 °C is 2.44.
The product contains phosphoric acid (7664-38-2) at less than 10%.
No, the product does not present an explosion hazard and is not flammable.
Rinse the affected eye for several minutes under running water. If symptoms persist, consult a doctor and remove contact lenses if present and easy to do.