Instruction sheet for the Fluke 772 and 773 milliamp process clamp meters, covering features, safety, operation, and measurement functions.
The Fluke 772 and 773 are hand-held, battery-operated milliamp process clamp meters used for troubleshooting transmitters, valves, PLC and DCS I/O. This instruction sheet covers safety information, controls, display, user options, and measurement procedures.
The meters support in-circuit 0-24 mA dc measurement and up to 99.9 mA dc with the remote clamp, plus sourcing and simulating functions; the 773 adds 0-10 V dc sourcing and 0-30 V dc measurement. Included accessories are four AA alkaline batteries, a soft carrying case, test leads, a detachable clip, mini hook test leads, and this instruction sheet.
| DC current measurement (clamp) | 0-24 mA dc and up to 99.9 mA dc |
|---|---|
| DC current sourcing/simulating | 0-24 mA dc |
| DC voltage sourcing (773) | 0-10 V dc |
| Loop power supply | 24 V dc output |
| DC voltage measurement (773) | 0-30 V dc |
| HART resistor | 250 Ω |
The meter comes with four AA alkaline batteries (installed), a soft carrying case, TL75 test leads, an AC 72 detachable clip, TL 940 mini hook test leads, and the instruction sheet.
Press C to zero the display, making sure the clamp jaws are closed and no current is flowing through them.
A positive reading indicates current flowing in the direction of the arrow on the clamp, while a negative reading indicates current flowing in the opposite direction.
The backlight automatically turns off after 2 minutes.