This manual provides operating instructions, safety information, and specifications for the Fluke 323, 324, and 325 True RMS Clamp Meters.


Fluke 323/324/325 Clamp Meter Users Manual - cover page
Brand
Fluke
Category
multimeter
Document type
User Manual
Language
English
Pages
26
File format
PDF
File size
1.3 MB
Published
12 November, 2026
Updated
12 November, 2026
MD5 checksum
1B7B8FFFFC994537C7645381DF71AD3F

About this manual

The Fluke 323/324/325 Clamp Meters are designed to measure AC and DC voltage, AC current, resistance, and continuity. The 324 and 325 models offer additional capabilities for measuring capacitance and contact temperature, while the 325 also measures DC current and frequency. These devices feature True RMS measurement and are rated for CAT III 600V and CAT IV 300V safety categories.

What's inside

  • Introduction
  • How to Contact Fluke
  • Safety Information
  • Specifications
  • The Meter
  • Operating Humidity
  • Environmental Specifications
  • Electrical Specifications
  • Mechanical Specifications

Specifications

AC Current Range (Jaw)323: 400.0 A; 324/325: (40.00, 400.0) A
AC Voltage Range600.0 V
DC Voltage Range600.0 V
Resistance Range323/324: (400.0, 4000) Ω; 325: (400.0, 4000, 40000) Ω
Operating Humidity≤90 % RH (at 10 °C to 30 °C)
Operating Altitude2000 meters
Safety ComplianceEN/IEC 61010-1, Pollution Degree 2

Frequently asked questions

What measurements can the Fluke 323 perform?

The Fluke 323 measures AC and DC voltage, AC current, resistance, and continuity.

What additional features do the 324 and 325 models have?

The 324 and 325 can measure capacitance and contact temperature, while the 325 also measures DC current and frequency.

What is the maximum operating temperature for the included thermocouple?

The included type-K thermocouple is rated to 260 °C.