Instruction manual for the Fisher CAV4 control valve and Cavitrol IV trim, covering installation, maintenance, and parts ordering.
The Fisher CAV4 control valve is an angle or globe (NPS 2 only) valve with soft metal-to-metal seats, Cavitrol IV trim, cage guiding, and push-down-to-close valve plug action. This instruction manual covers installation, maintenance, and parts ordering for the valve and Cavitrol IV trim, including information on flushing trim.
Specifications include available configurations, end connection styles, shutoff classifications, flow direction, flow characteristic, and approximate weights. Maintenance topics include packing lubrication and replacement, trim removal and replacement, and use of optional flushing trim.
| Body type | Angle or globe (NPS 2 only) |
|---|---|
| Trim | Cavitrol IV trim |
| Seats | Soft metal-to-metal seats |
| Flow characteristic | Linear |
| Flow direction, angle bodies | In through side connection, out bottom connection |
| Flow direction, globe bodies | Flow down |
| End connections | Buttwelding ends; raised-face or ring-type joint flanged ends |
| Maximum inlet pressure, temperature, and pressure drops | Consistent with ASME B16.34 CL1500 and CL2500 ratings |
| Shutoff classification | TSO (tight shutoff) trim |
It covers installation, maintenance, and parts ordering information for the Fisher CAV4 control valve and Cavitrol IV trim, including flushing trim information.
It is most often used to help eliminate cavitation damage on liquid service where the differential pressure drop is greater than 207 bar (3000 psi).
Liquid enters through the side connection, undergoes four staged pressure drops, and leaves through the bottom connection.
By the letters SMS stamped on the seat ring or lower cage assembly.