Installation guide for Fisher 627 Series pressure regulators covering configurations, pressure ratings, temperature limits, and installation instructions.
This installation guide provides installation, startup, and adjustment instructions for Fisher 627 Series pressure regulators. It lists available configurations including Types 627, 627R, 627LR, 627M, 627MR, 627H, and 627HM, and covers PED categories, body sizes and end connection styles, maximum inlet pressures, and elastomer temperature capacities.
The document also includes Table 1 for pressure ranges by orifice size and spring range, along with installation precautions. It states that only qualified personnel should install or service a regulator and directs users to clean piping, check for damage or foreign material, and confirm flow direction by the arrow stamped on the body. This manual is written in Spanish.
| PED category, DN 20 to 25 / NPS 3/4 to 1 | SEP 1 |
|---|---|
| PED category, DN 50 / NPS 2 | II |
| Maximum inlet pressure, stainless steel NPT | 138 bar / 2000 psig |
| Maximum inlet pressure, flanged stainless steel | 99.3 bar / 1440 psig |
| Maximum inlet pressure, ductile iron | 69.0 bar / 1000 psig |
| Maximum inlet pressure, Nylon (PA) valve disc | 138 bar / 2000 psig |
| Maximum inlet pressure, Nitrile (NBR) valve disc | 69.0 bar / 1000 psig |
| Maximum inlet pressure, fluorocarbon (FKM) valve disc | 20.7 bar / 300 psig |
| Nitrile (NBR) disc temperature range | -40 to 82°C / -40 to 180°F |
| Fluorocarbon (FKM) disc temperature range | -18 to 82°C / 0 to 180°F |
Type 627R is a Type 627 with an internal relief valve and open neck.
The maximum inlet pressure is 138 bar / 2000 psig.
The PED category is Category II.
The arrow stamped on the body indicates the flow direction.