This manual covers the installation, adjustment, maintenance, and parts ordering for Fisher 1301F and 1301G high-pressure regulators.
This instruction manual provides guidance for the Types 1301F and 1301G high-pressure regulators, which are direct-operated devices used to reduce high-pressure gas for pilot supply or loading pressure in other regulators. They are suitable for various fluids including air, gas, water, and other liquids.
| Inlet Pressure (Brass Body, Air/Gas) | 6000 psig / 414 bar |
|---|---|
| Inlet Pressure (Stainless Body, Air/Gas) | 6000 psig / 414 bar |
| Outlet Pressure Range (1301F) | 10 to 225 psig |
| Outlet Pressure Range (1301G) | 200 to 500 psig |
| Maximum Emergency Outlet Pressure (1301F) | 250 psig / 17.2 bar |
| Maximum Emergency Outlet Pressure (1301G) | 550 psig / 37.9 bar |
| Approximate Weight | 8 pounds / 4 kg |
They can be used for various fluids such as air, gas, water and other liquids.
First close the upstream shutoff valve, then close the downstream shutoff valve, and finally open the vent valves.