Technical support document for Orion BMS fault code P0A04, detailing causes, behavior, thresholds, and diagnostic steps for open wiring faults.
This document provides technical support for the Orion BMS family, specifically addressing fault code P0A04, which indicates an open or high resistance connection in cell tap wires. The supported product families include Orion BMS (24-180 Cell), Orion BMS 2 (24-180 Cell), Orion JR (16 Cell), and Orion JR 2 (16 Cell).
| Test Interval | Every 15 seconds |
|---|---|
| Trigger Count | At least 3 triggers |
| Hysteresis | One minute |
It indicates an open or high resistance connection was detected by the BMS on one or more cell tap wires.
The system triggers Voltage Failsafe Mode, which inhibits charging or discharging of the battery pack.
The code is supported by Orion BMS (24-180 Cell), Orion BMS 2 (24-180 Cell), Orion JR (16 Cell), and Orion JR 2 (16 Cell).