Ewert Energy Systems Orion Jr. 2 BMS battery management system wiring and installation manual
This manual provides wiring and installation instructions for the Orion Jr. 2 Battery Management System (BMS) designed for lithium ion battery packs. It covers safety precautions, physical mounting, and detailed electrical wiring procedures for main connectors, CAN interfaces, digital signals, and voltage taps. The document emphasizes the importance of proper integration by qualified personnel to prevent damage and ensure safety.
| Maximum Working Voltage | 60 volts DC |
|---|---|
| Nominal Voltage | 48 VDC |
| Cell Support | 1 to 16 cells |
Integration must be performed by a qualified person trained in electrical engineering and familiar with the characteristics and safety requirements of lithium batteries.
No, the Orion Jr. 2 is not to be used for life support systems, medical applications, or other applications where a failure could cause damage to property or cause bodily harm or death.
Damaged units should be immediately disconnected from all power including the battery pack and removed from service. Users should never attempt to repair an Orion Jr. 2 BMS unit.