Enterprise Plus Series UPS User's Manual

User's manual for the Enterprise Plus Series UPS covering controls, installation, operation, troubleshooting, battery replacement and specifications.


Enterprise Plus Series UPS User's Manual - cover page
Category
Power Management
Document type
User Manual
Language
English
Pages
32
File format
PDF
File size
1.8 MB
Published
16 November, 2026
Updated
16 November, 2026
MD5 checksum
98030A7977CFBA01CE03F29D8FBF0272

About this manual

This User's Manual covers the Enterprise Plus Series UPS in models E750RM2U, E1000RM2U, E1500RM2U, E1500RMT2U, E2000RM2U, E3000RM2U and E3000RMT2U. It describes the control panel LEDs, the load level and battery capacity bar graphs, the multi-function On/Off/Test button, and the rear panel ports, including the RS232 and USB communications interface ports, the RJ11 REPO port, an option slot and the external battery connector.

The manual gives safety instructions, receiving inspection notes, installation and operation instructions, troubleshooting guidance, battery replacement steps, service information, specifications, configurable parameters and settings, the limited product warranty and a declaration of conformity. It also includes a life support policy and notes that the document carries a 2006 copyright notice.

What's inside

  • Introduction
  • Controls and Indicators
  • Installation
  • Operation
  • Troubleshooting
  • Replacing the Battery
  • Obtaining Service
  • Specifications
  • Configurable Parameters & Settings
  • Limited Product Warranty

Specifications

Combined AC leakage currentMust not exceed 3.5 mA
Power cord length10 ft
Self test duration5 seconds
Communications and control portsRS232 port, USB port, RJ11 REPO port and option slot
Radio noise complianceClass B computing device limits, FCC Rules Part 15 Subpart J

Frequently asked questions

How do I turn the UPS on?

When the UPS is off, press and release the On/Off/Test button after one beep. For 208V models the input circuit breaker must be in the on position.

What does the Weak/Bad Battery LED indicate?

It illuminates steady when the UPS detects a weak battery, a bad battery or a disconnected battery, and is extinguished when the battery condition is good.

Are the batteries connected when the UPS is shipped?

No. The UPSs are shipped with the batteries disconnected and the batteries must be connected before putting the UPS into service.

How long is the UPS self test?

When the UPS is on, press and hold the On/Off/Test button for four beeps and release; the UPS performs a 5-second self test.