Diris A40/A41 is a device used to measure and measure the electrical parameters of single phase, 2 phase and 3 phase low / high voltage networks. It can set and display all parameters and implement standard functions for multi-parameter measurement, power measurement, harmonic distortion calculation, operating time measurement, wiring error testing, and provide RS485 communication function, multiple harmonic analysis, analog output and monitoring or inspection/control (output/input) function.
About this manual
The Diris A40/A41 is a multi‑function ammeter for single‑phase, two‑phase and three‑phase low‑ and high‑voltage networks. It measures voltage, current, power, energy, harmonic distortion and operating time, and can be expanded with optional RS485 communication, analog output, pulse output and monitoring modules.
The manual provides detailed physical description, mounting instructions, wiring diagrams, safety specifications, module installation procedures, network configuration for balanced and unbalanced systems, and step‑by‑step instructions for entering setting mode and performing repetitive tests. This manual is written in Chinese.
What's inside
- Product Description
- Functions
- Optional Modules
- Physical Appearance
- Installation
- Wiring and Safety
- Settings Procedure
Specifications
| Effective energy measurement range | 0 to 99,999,999 kWh |
|---|
| Reactive energy measurement range | 0 to 99,999,999 kvarh |
|---|
| Apparent energy measurement range | 0 to 99,999,999 kVAh |
|---|
| Maximum voltage input | 700 V AC line or 404 V AC phase |
|---|
| Supported protocols | JBUS/MODBUS or PROFIBUS DP |
|---|
| Maximum terminal screw torque | 0.4 Nm |
|---|
| Auxiliary power supply range | 110‑400 V AC (+‑10%) or 120‑350 V DC (+‑20%) |
Frequently asked questions
How do I enter the setting mode?
Press and hold the PROG key for 3 seconds, release it, then press once.
What is the maximum torque for the wiring terminal screws?
Each terminal screw must not exceed a torque of 0.4 Nm.
What voltage ranges are allowed for the auxiliary power supply?
The auxiliary supply can be 110‑400 V AC (±10 %) or 120‑350 V DC (±20 %).