Emotron TSA and MSF Softstarters Technical Catalogue

Technical catalogue detailing specifications, ratings, and dimensions for Emotron TSA and MSF electronic softstarters.


Emotron TSA and MSF Softstarters Technical Catalogue - cover page
Brand
Emotron
Category
Motor
Document type
Product Leaflet
Language
English
Pages
24
File format
PDF
File size
2.8 MB
Published
04 November, 2026
Updated
04 November, 2026
MD5 checksum
1C7F2AA49C2D16E8A445B78DED49B740

About this manual

This document serves as a technical catalogue for the Emotron TSA and MSF series of electronic softstarters. It covers power ranges from 4 kW to 1.6 MW and voltages from 200 V to 690 V. The TSA series features a compact design with an integrated bypass, while the MSF series is designed for heavy-duty applications with robust metal enclosures. Both models offer features such as torque control, dynamic vector braking, and load monitoring.

What's inside

  • Main features
  • Typical motor power
  • General specifications
  • Environmental conditions
  • Environmental conditions
  • Storage condition
  • CAD drawings

Specifications

Power range4 kW - 450 kW (TSA); 4 kW - 1.6 MW (MSF)
Voltage range200 - 690 V
Mains frequency50/60 Hz
Nominal ambient temperature0 °C–40 °C
Maximum altitude4,000 m
Protection class (TSA)IP20
Protection class (MSF)IP20 or IP00

Frequently asked questions

What is the start current for normal duty?

The start current is 3 times the softstarter rated current (3 x In.soft).

What is the start current for heavy duty?

The start current is 5 times the softstarter rated current (5 x In.soft).

Does the TSA softstarter have an integrated bypass?

Yes, the TSA softstarter includes an integrated bypass with proven contactor technology.