Emotron M20 Shaft Power Monitor Instruction Manual

This is an instruction manual for the Emotron M20 Shaft Power Monitor. It introduces the features and characteristics of the product, including the connection and setup methods, the operation methods, and the programming methods.


Emotron M20 Shaft Power Monitor Instruction Manual - cover page
Brand
Emotron
Category
Industrial Robot
Document type
User Manual
Language
English
Pages
56
File format
PDF
File size
1.6 MB
Published
18 October, 2023
Updated
18 October, 2023
Model
M20
MD5 checksum
F83BDBFAF915B3A309F654EE4EC97A9D

About this manual

The Emotron M20 shaft power monitor is designed to supervise induction motor driven equipment, such as pumps and conveyors, by measuring shaft power. It calculates this by measuring motor input power and subtracting motor power losses using a unique principle, allowing for accurate monitoring of the actual application load rather than total motor load. The device requires no external sensors or extra cabling, as it uses the motor itself as a sensor.

The manual covers the unboxing process, safety precautions, and step-by-step connection and setup procedures. It details how to set parameters such as rated motor power, current, alarm levels, and response delays via the unit's menu system. The document also includes troubleshooting guidance and technical data.

What's inside

  • Inside the Box
  • Safety
  • Description
  • Getting Started
  • Connection and set-up
  • Manual setting of alarm levels
  • Advanced Features
  • Troubleshooting
  • Technical Data
  • Parameter List

Specifications

Product TypeShaft Power Monitor
ManufacturerEmotron AB
Document Date06-30-2008

Frequently asked questions

What applications is the Emotron M20 suitable for?

It is ideal for protecting applications including pumps (centrifugal, magnetic, screw, impeller), mixers, scrapers, crushers, and conveyor systems.

Does the Emotron M20 require external sensors?

No, the monitor uses the motor as its own sensor and no external sensors or extra cabling are required.

How is shaft power calculated by the M20?

It is calculated by measuring motor input power and subtracting the motor power loss calculated using a unique principle.