ELKO EP AirIM-100L Wireless Input Converter User Manual

ELKO EP AirIM-100L wireless input converter user manual for installation, functions, and battery replacement.


ELKO EP AirIM-100L Wireless Input Converter User Manual - cover page
Brand
ELKO EP
Category
Other Electronics
Document type
User Manual
Language
CS
Pages
40
File format
PDF
File size
2.2 MB
Published
15 November, 2026
Updated
15 November, 2026
MD5 checksum
2D741C07865B2B3DDF0278CE7D2F8A56

About this manual

ELKO EP AirIM-100L is a wireless input converter for detecting device states in residential and industrial use. It provides pulse, analog, and binary inputs and terminals for a temperature sensor, and can be used with sensors for level, temperature, gas, water, or electricity consumption, flooding, and similar monitoring. Data is sent over a LoRa network to a server for viewing in a smartphone app or cloud, and the device includes an anti-tamper function.

The manual covers mounting, function selection, connection diagrams, device states, and battery replacement. The converter supports 5-12 V DC or one 3.6 V AA Li-SOCl2 battery and has IP65 protection. It uses LoRa frequency bands for India, Europe, and North America, Japan, and Korea. This manual is written in Czech.

What's inside

  • Device description
  • Cloud app assignment
  • IoT general instructions
  • LoRa network
  • Installation
  • Functions
  • Function settings
  • Device states
  • Battery replacement

Specifications

Power supply5-12 V DC or 1 x 3.6 V AA Li-SOCl2 battery
Ingress protectionIP65
Cable glandM16x1.5 for cable up to 10 mm diameter
Wall mounting hole4.3 mm diameter
LoRa frequency band (India)865-867 MHz
LoRa frequency band (Europe)867-869 MHz
LoRa frequency band (North America, Japan, Korea)902-928 MHz
Pulse reportingEvery 4 hours; immediately above 5000 pulses

Frequently asked questions

What power supply options does the AirIM-100L support?

It supports 5-12 V DC or one 3.6 V AA Li-SOCl2 battery.

How often are pulse counts reported?

Measured values are sent every 4 hours, and immediately when the count exceeds 5000 pulses.

What happens when the device is tampered with?

A message is sent to the server immediately.

Which LoRa frequency bands are used?

The bands are 865-867 MHz in India, 867-869 MHz in Europe, and 902-928 MHz in North America, Japan, and Korea.