User manual for the Elitech LogEt 8 Series data logger, covering configuration, operation, data download, and battery replacement for temperature and…
The Elitech LogEt 8 Series data loggers feature an LCD screen and two buttons, supporting various start and stop modes, multiple threshold settings, and two storage modes including cyclic recording. The device automatically generates PDF reports for users to check data without requiring software. It is designed for temperature and humidity monitoring in storage and cold chain logistics environments.
| Resolution (Temperature) | 0.1°C / 0.1°F |
|---|---|
| Resolution (Humidity) | 0.1%RH |
| Memory Capacity | 16,000 points (MAX) |
| Logging Interval | 10 seconds ~ 24 hours |
| Battery Type | 3.6V disposable lithium battery 14250H |
| Protection Level | IP65 |
| Dimensions | 100 x 46 x 19 mm (LxWxH) |
| Temperature Accuracy | ±0.3°C (-20°C ~ 40°C) |
| Humidity Accuracy | ±3%RH (25°C: 20%RH ~ 80%RH) |
Press and hold the left button for 5 seconds until the icon shows on the LCD.
Press and hold the right button for 5 seconds until the icon shows on the LCD.
The battery lasts for 2 years for storage and use at a 10-minute logging interval and below 25°C.