Elitech RCW-400 Remote Logging Alarm Monitoring Instrument User Manual

The RCW-400 is a dual-channel temperature and humidity recorder with a wide temperature measurement range and high accuracy. The segment LCD screen can simultaneously display the system clock, current working status, recording capacity and recording data. It has蜂鸣器and relay alarm output functions, and has wireless GPRS data transmission mode. Combined with the cold chain IoT platform, it can view temperature and humidity data on any Internet-enabled terminal at any time. At the same time, it can also send SMS alarms through GSM. Customers can view and manage monitoring data remotely online through a browser. You can view and manage monitoring data in real time through smart phone terminal software.


Elitech RCW-400 Remote Logging Alarm Monitoring Instrument User Manual - cover page
Brand
Elitech
Category
Temperature monitor
Document type
User Manual
Language
Chinese
Pages
13
File format
PDF
File size
644 KB
Published
15 November, 2023
Updated
15 November, 2023
MD5 checksum
3BE5BB386BF2E9D25C0FD359D7F5ACFE

About this manual

The RCW-400 is a dual-channel temperature and humidity data logger from Elitech (精创电气). It has a wide temperature measurement range and high accuracy, a segment LCD showing time, working status, record count and data, plus buzzer and relay alarm outputs. Data is transmitted wirelessly over GPRS and can be viewed remotely through the Elitech cold-chain IoT platform in a browser or smartphone app, and the device can send alarm SMS over GSM.

The manual covers the product display and LCD symbols, installation of accessories and the SIM card, device activation and phone binding on the platform, SMS alarm commands, parameter settings, technical specifications, standard and optional accessories, and troubleshooting. The standard configuration is 1 temperature and 1 humidity sensor, expandable to 2 temperature/2 humidity or 4 temperature channels, and the built-in rechargeable lithium battery keeps the unit reporting and alarming for at least 6 hours after a cold-storage power failure. This manual is written in Chinese.

What's inside

  • 产品介绍 (Product introduction)
  • 产品显示 (Product display)
  • 产品安装 (Product installation)
  • SIM 卡安装和更换 (SIM card installation and replacement)
  • 设备激活 (Device activation)
  • 手机绑定 (Phone binding)
  • 短信报警功能指令列表 (SMS alarm command list)
  • 参数设置 (Parameter settings)
  • 技术指标 (Technical specifications)
  • 故障排除 (Troubleshooting)

Specifications

Power supply12V AC/DC – 24V AC/DC, via external adapter 100–264VAC, 50/60Hz
Temperature measurement range-50℃ to +99℃
Temperature accuracy±1.0℃ (-25–0℃), ±0.5℃ (0–40℃), ±2℃ elsewhere
Display resolution0.1
Humidity measurement range10–95%RH
Temperature sensor typeNTC thermistor
Humidity sensor typeHoneywell
Recording interval1 minute to 24 hours, continuously adjustable
Recording capacity2000 data groups per channel
Operating environment-10℃ to 45℃, 0–95%RH, indoor use
Alarm outputBuzzer and relay
Communication interfacesGPRS, SMS
Backup battery3.7V 2200mAH lithium battery

Frequently asked questions

How do I activate the RCW-400?

Add the Kugou (库狗) ID and administrator number on the Elitech cold-chain IoT platform, then send the administrator number to the device by SMS and finally send the device its own 20-digit ID by SMS; a success SMS confirms activation.

How do I bind my phone to the RCW-400?

About 3 minutes after connecting power, send the SMS "设定000" to the phone number in the device; after receiving the binding-success message, follow the SMS prompts. The first bound number becomes the administrator.

How long does the RCW-400 keep working after a power failure?

After the external power is disconnected, the built-in battery keeps it working for at least 6 hours, continuing data upload and SMS alarms.

The display shows --.-℃ or --.-%. What should I do?

The sensor is not connected or has a poor connection; check that the wire colors match the wiring label.

Download PDF (644 KB)

More Elitech Manuals