Installation manual for ELEKTRA SnowTec and SnowTec Tuff heating mats, covering applications, cable structure, technical data, controls, and installation steps.
ELEKTRA SnowTec and SnowTec Tuff heating mats are ready-made units intended to prevent snow and ice deposition on driveways, roads, parking spaces, terraces, viaducts, bridges, and loading ramps. Depending on the surface, they are laid in a layer of sand or dry concrete, directly in concrete, or, for SnowTec Tuff, directly in asphalt.
The manual describes the cable structure, dimensions, heat output, supply voltages, minimum installation temperatures, and controls including ELEKTRA ETR2 and ETO2 DIN-bus controllers, plus ETOG2, ETR2G, and SMCG snow and ice protection controls. It also gives installation stages and notes on joints, cold tails, and surface preparation.
| Width (SnowTec) | 40 and 60 cm |
|---|---|
| Width (SnowTec Tuff) | 60 cm |
| Length (SnowTec) | 2 to 25 m |
| Length (SnowTec Tuff) | 1.5 to 27 m |
| Thickness | Approx. 7.5 mm |
| Cold tail length | 4 m |
| Surface heat output (SnowTec) | 300 W/m2 |
| Surface heat output (SnowTec Tuff) | 400 W/m² |
| Power supply (230 V models) | 230 V |
| Power supply (400 V models) | 400 V |
| Minimum installation temperature | -5°C (SnowTec); -25°C (SnowTec Tuff) |
They are intended to prevent snow and ice deposition on driveways, roads, parking spaces, terraces, viaducts, bridges, and loading ramps.
Yes. SnowTec Tuff mats can be installed directly in asphalt, and they can also be installed directly in concrete.
SnowTec and SnowTec Tuff mats are rated for 230 V, 50 Hz; the 400V versions are rated for 400 V, 50 Hz.
No. The heating cable must never be cut; only the cable connecting tape can be cut to shape the mat.