ELEKTRA VCD10 and VCD17 heating cables are primarily intended for use in rooms with a tile or natural stone floor covering.
This manual provides installation instructions for the ELEKTRA VCD10 (10 W/m) and VCD17 (17 W/m) heating cables. These cables are primarily designed for use with tile or natural stone floors but can also be used with fitted carpets, vinyl flooring, parquet, and laminate, provided the floor covering is suitable for electric underfloor heating.
The document details the installation process on slab floors or concrete subfloors using thermal insulation and anhydrite or cement screed. It specifies that cables should not be cut, shortened (except the power supply conductor), or stretched excessively. The manual also outlines minimum spacing requirements between cables based on floor type and screed characteristics.
| Heat output VCD10 | 10 W/m |
|---|---|
| Heat output VCD17 | 17 W/m |
| Power supply voltage | 230 VAC, 50/60 Hz |
| External dimensions | < 5 x 7mm |
| Min. installation temperature | -5°C |
| Min. cable bending radius | 3.5D |
They are primarily intended for tile or natural stone floors, but can also be used with fitted carpets, vinyl flooring, parquet, and laminate.
No, the heating cable itself should never be cut or shortened; only the power supply conductor may be shortened if required.