ecom D Flue Gas Analyzer Operating Instructions

Operating instructions for the ecom‑D flue gas analyzer covering setup, measurement, data logging, maintenance and technical specifications.


ecom D Flue Gas Analyzer Operating Instructions - cover page
Brand
ECOM
Document type
User Manual
Language
English
Pages
48
File format
PDF
File size
1.3 MB
Published
30 September, 2026
Updated
30 September, 2026
MD5 checksum
2187088A388A8186F4E6605E42DD0F33

About this manual

The ecom‑D flue gas analyzer provides intelligent analysis of combustion gases. This manual explains instrument design, optional gas cooler, power supply, data memory, and step‑by‑step start‑up procedures. It also details selection of combustion plants, flue‑gas measurement methods, mean‑value calculations, adjustments, control functions, and data processing options.

Additional sections cover maintenance tips, technical data such as measurement ranges and power requirements, and a FAQ that answers common operational questions. The document includes specifications for the built‑in printer, battery, and optional accessories.

What's inside

  • Instrument Design
  • Gas Cooler (option)
  • Power Supply
  • Data Memory
  • Instrument Start
  • Flue Gas Analysis
  • Mean Value Measurement
  • Adjustments
  • Control
  • Data Processing

Specifications

O₂ measurement range0 – 21 % vol.
CO measurement range0 – 10,000 ppm
Power supply voltage110 – 230 V, 50‑60 Hz
Battery life (internal)3 – 5 hours
Pump flow rate0.8 – 1.0 l/min
Dimensions (L × W × H)≈ 7.25" × 3.0" × 5.0"
Weight≈ 3.5 lb

Frequently asked questions

Can the ecom‑D be used for continuous emission control?

No, the ecom‑D should not be used for continuous emission control.

How often should the internal battery be charged?

The internal battery should be charged at least once per month when the analyser is not in use.

What type and size of memory card can be used?

A multi‑media card with a capacity between 32 MB and 32 GB, formatted as FAT16 or FAT32, is required.

What is the required power supply voltage range?

The analyser can be powered from 110 V to 230 V at 50‑60 Hz.