This document gives installation instructions for the DSC BV-600 Brave dual PIR motion detector. It explains how to choose a detector location to avoid false alarms, how to open the case and mount the backplate, and how to set the vertical adjustment using the mounting height chart. Jumper settings for the alarm LED (J1) and for normal or harsh environments (J2) are described, followed by walk testing and a note that the end user should walk test the detector weekly.

The document also lists the models BV-600, BV-601 and BV-602, gives the vertical height guide and wiring notes, and provides full specifications including voltage, current, contact rating, temperatures, coverage angle, mounting heights, walk detection speed and pet immunity. It ends with the twelve-month limited warranty from Digital Security Controls Ltd. and notes on how passive infrared detectors work.

What's inside

  • Locating the Detector
  • Mounting
  • Vertical Adjustment
  • Jumper Settings
  • Walk Testing
  • Specifications
  • Models
  • Vertical Height Guide
  • Wiring
  • Limited Warranty

Specifications

Operating voltage9.5 VDC - 14.5 VDC
Standby current16.5 mA
Current in alarm (LED ON)17.5 mA
Contact rating (alarm and tamper)100 mA @ 24 VDC
Operating temperature0 °C to 49 °C (32 °F to 120 °F)
Dimensions124.5 mm × 70 mm × 44.5 mm (4.9 in H × 2.76 in W × 1.75 in D)
ColourWhite with white lens
Coverage angle (wall/wall lens)100° maximum
Vertical adjustment+2° to -5°
Mounting heights7 ft - 10.5 ft (2.1 m - 3.2 m), nominal 7.5 ft / 2.3 m
Walk detection speed0.5 ft/s - 10 ft/s (0.15 - 3 m/s)
Pet immunityPets under 2.5 ft / 0.75 m (up to 85 lbs / 38 kg)
Static immunity15 kV

Frequently asked questions

How do I turn the alarm LED on or off?

Jumper J1 enables or disables the alarm LED. If J1 is OFF the LED does not operate on alarm; if J1 is ON the LED operates on alarm.

What is jumper J2 used for?

J2 selects between harsh and normal environments. For a typical environment or a small pet lower than 1.2 ft (0.36 m) set the unit as normal (J2 ON); for a large pet, remove J2.

What is the difference between the BV-600, BV-601 and BV-602 models?

The BV-600 has a Form 'A' alarm contact. The BV-601 adds a tamper switch to the Form 'A' alarm contact, and the BV-602 has a Form 'C' alarm contact with a tamper switch.

How often should the detector be walk tested?

The area should be walk tested after setup, and the end user should be instructed how to perform walk tests and should walk test the detector weekly.

Download PDF (373 KB)